Following the most rigorous quality standards, including strict color meter testing, Clariant's humidity indicator cards and humidity indicator plugs are designed to meet standards set forth by military agencies and electronic/semiconductor compa
New Equipment | Education/Training
This 3-day, lectured course utilizes the images in the IPC-A-610 inspection document to provide visual accept/reject criteria examples for all three classes of assembly production–in both lead and lead-free. The IPC-A-610, “The Acceptabil
Electronics Forum | Thu Apr 12 00:56:20 EDT 2007 | Jani
Our SMT production and storage area is air-conditioned, constant temperature is maintained but the humidity is not controlled , the raw SMT material is stored in a "Drier" cabinet, but since we assemble hybrid SMT and thru-hole PCB assemblies, the SM
Electronics Forum | Thu Apr 12 13:04:47 EDT 2007 | slthomas
Handling requirements of all classifications of moisture sensitive devices is found in J-STD-033. It really isn't an issue for most parts unless they're going to reach reflow temperature again, which is unlikely unless you're removing a nearby compo
Industry News | 2020-05-27 15:54:35.0
Blackfox is opening its facilities to in-person training for the electronics manufacturing industry with a thorough and documented safety plan for all. If preferred, Blackfox is also offering online IPC training and certification in either English or Spanish from the comfort of your home or office.
Industry News | 2009-06-16 12:26:28.0
New Five-Day Class Teaches Practical as well as Lecture
Technical Library | 2019-06-21 10:39:15.0
Recently, an ACI Technologies (ACI) customer called to discuss failures that they had observed with some through-hole capacitor parts. The components were experiencing failures following vibration and accelerated stress testing. Upon receipt of the samples, ACI performed three levels of inspection and Energy Dispersive Spectroscopy (EDS) testing to investigate the root cause of the failures. These analyses enabled ACI to verify the elements comprising the solder joints and make the following recommendations in order to prevent future occurrences. The first inspection was to investigate the capacitor leads using optical microscopy, and no anomalies were found that could indicate bad parts from the vendor or improper handling prior to assembly. However, vertical fill in the barrel of the plated through-holes was too close to the IPC-A-610 minimum specification of 75% to determine a pass/fail condition, and therefore required further investigation.
Technical Library | 2019-11-17 22:46:45.0
Overview of walk-in temperature and humidity chamber: It also belongs to environmental test equipment, it tests whether the product can resist high temperature, low temperature, humidity, or the physical and chemical changes produced under extreme conditions, the walk-in temperature and humidity chamber volume is large, the product is placed, or a large object can be placed, such as automobile, new energy, television and liquid crystal screen, etc. How to do the routine maintenance of the walk-in temperature and humidity chamber: 1. The wet gauze basically, if there is no special case, s/b usually changed once in 3 months 2. The water channel shall be regularly cleaned, including water cup, water tank, etc., so as to prevent the water from being blocked,affect the humidity test. 3. It is forbidden to test the flammable and explosive products inside working room. 4. Clean the chamber on a regular basis 2. How to operate walk-in temperature and humidity chamber: The operation method is same as standard temperature humidity test chamber,the controller is 7-inch LCD programmable color screen, you only need to setthe temperature point---test time--how many cycles need to be tested, This can be done automatically, and the machine will stop automatically when it is complete. If there is any problem during the operation, the corresponding problem point will be displayed on the machine control screen. Walk-in temperature and humidity chamber is a must equipment for reliability test of Automobile,Aerospace,Electronic parts,etc,the operation and maintenance are easy,it is teh tear down mahcine,Climatest engineers will be dispatched to do on-site support,for instance,we will finish commissioning,train customers how to operate,maintain,welcome to follow our company facebook page:https://www.facebook.com/Climatechambers
This 4-day, lectured course utilizes the images in the IPC-A-610 document to provide visual accept/reject criteria examples for all three classes of assembly production–for both lead and lead-free. The IPC-A-610, “The Acceptability of Ele
Following the most rigorous quality standards, including strict color meter testing, Clariant's humidity indicator cards and humidity indicator plugs are designed to meet standards set forth by military agencies and electronic/semiconductor compa
Training Courses | | | PCB Rework and Hand Soldering Courses
The PCB rework and hand soldering courses courses cover techniques of rework and repair of PCBs, BGAs and other electronics assemblies, and teach fundamentals of soldering of electronics assemblies.
Events Calendar | Tue Sep 10 00:00:00 EDT 2019 - Tue Sep 10 00:00:00 EDT 2019 | Huntsville, Alabama USA
IPC Tech Ed - Process and Acceptability Requirements: Utilizing J-STD-001 and IPC-A-610 Together
Events Calendar | Tue Dec 03 00:00:00 EST 2019 - Tue Dec 03 00:00:00 EST 2019 | Anaheim, California USA
IPC Tech Ed - Process and Acceptability Requirements: Utilizing J-STD-001 and IPC-A-610 Together
Career Center | Orlando, Florida USA | Production
Position Summary: Build through-hole (THT) and surface mount (SMT) printed circuit board assemblies, placing components on boards per controlled parts lists, drawing documentation and quality workmanship guidelines. Position reports to: Group Lea